    Photon Cross-Correlation Spectroscopy (PCCS) | Particle Size and Stability of Nanosuspensions from 0.5 nm to 10,000 nm

     

    In general, the acquisition of scattered light intensities of particles under thermal motion is deployed for nanoparticle characterisation (principle of dynamic light scattering (DLS)). The method known as Photon Correlation Spectroscopy (PCS) applies auto-correlation of scattered light intensities in order to determine particle size distribution. However, this conventional technology requires extremely diluted samples in order to deliver meaningful results.

    NANOPHOX brings Photon Cross-correlation Spectroscopy (PCCS) to life, which allows for nanoparticle size analysis in turbid suspensions and emulsions ranging from 0.5 nm to 10,000 nm at up to a hundred times higher solid contents. The outstanding technological feature of NANOPHOX is the acquisition of two separately induced scattered light intensities which then are cross-correlated. This allows for robust measurement even at higher sample concentrations. In addition to size, the aggregation or sedimentation behaviour of nanosuspensions (i.e. stability) may be analysed. Typical applications comprise e.g., polymer emulsions, colloidal silica, inks and research on nanodispersions in general.

     

    PCCS advantages

    • Robust method for research, development and quality control
    • Concentration independent particle characterisation by elimination of multiple scattering effects
    • Extension of conventional PCS provides concurrent measurements of particle size and stability in opaque suspensions and emulsions
    • Easy sample preparation without undesired dilution series
    • Insensitive to sample contamination
    • No required cleanroom conditions
    • Direct measurement of stability, agglomeration and sedimentation of slightly charged (electro-steric stabilised) to uncharged (steric stabilised) particles of turbid samples
    • Analysis of special effects such as particle-particle  interactions and changes in viscosity in high-concentrated samples
    • High sensitivity for changes in size and measurement of bimodal distributions
    • Solid-state measuring method for in-situ observation of changes in stability or size, e.g. growth and crystallisation processes
    • Wide concentration range by PCS and PCCS united

     

    NANOPHOX – Nanoparticle Measurement in Primary Condition

    As a professional pioneer of PCCS we are offering the first table top instrument based Photon Cross-Correlation Spectroscopy (PCCS). With this we consequently follow our strategy of developing innovative instruments which measure the sample as close as possible to its original state. The NANOPHOX system together with its powerful PAQXOS control and evaluation software is fully compliant with FDA requirements and 21 CFR Rule 11.

Send your message to this supplier
  • From:
  • To:
    Sympatec GmbH – System | Partikel | Technik
  • Send a Copy to this Email
  • Message:
    Upload Images / Files
    - Supports jpg, jpeg, png,
     gif, pdf, doc, docx,
     xls, xlsx, txt, rar and zip
    - Max upload 3 files;
     Max  total size: 3MB
    (0/3)

    Enter between 20 to 4,000 characters.This is not what you are looking for ? Post a Sourcing Request Now

  • Verification:
PharmaSources Customer Service